  1. 1
  2.  
  3.  
  4.  
  5.                                  ************************************
  6.  
  7.                                     NUMERICAL ELECTROMAGNETICS CODE
  8.  
  9.                                  ************************************
  10.  
  11.  
  12.  
  13.  
  14.                                      - - - - COMMENTS - - - -
  15.  
  16.  
  17.                          EXAMPLE 1.  CENTER FED LINEAR ANTENNA                                       
  18.  
  19.  
  20.  
  21.  
  22.                                  - - - STRUCTURE SPECIFICATION - - -
  23.  
  24.                                      COORDINATES MUST BE INPUT IN
  25.                                      METERS OR BE SCALED TO METERS
  26.                                      BEFORE STRUCTURE INPUT IS ENDED
  27.  
  28.  
  29.   WIRE                                                                               NO. OF    FIRST  LAST     TAG
  30.   NO.        X1         Y1         Z1          X2         Y2         Z2      RADIUS   SEG.     SEG.   SEG.     NO.
  31.      1     .00000     .00000    -.25000      .00000     .00000     .25000     .00100      7        1     7       0
  32.  
  33.    TOTAL SEGMENTS USED=    7     NO. SEG. IN A SYMMETRIC CELL=    7     SYMMETRY FLAG=  0
  34.  
  35.  
  36.          - MULTIPLE WIRE JUNCTIONS -
  37.  JUNCTION    SEGMENTS  (- FOR END 1, + FOR END 2)
  38.   NONE
  39.  
  40.  
  41.  
  42.  
  43.                                  - - - - SEGMENTATION DATA - - - -
  44.  
  45.                                         COORDINATES IN METERS
  46.  
  47.                          I+ AND I- INDICATE THE SEGMENTS BEFORE AND AFTER I
  48.  
  49.  
  50.   SEG.   COORDINATES OF SEG. CENTER     SEG.     ORIENTATION ANGLES    WIRE    CONNECTION DATA   TAG
  51.   NO.       X         Y         Z       LENGTH     ALPHA     BETA      RADIUS    I-   I    I+    NO.
  52.      1    .00000    .00000   -.21429    .07143   90.00000    .00000    .00100     0    1    2      0
  53.      2    .00000    .00000   -.14286    .07143   90.00000    .00000    .00100     1    2    3      0
  54.      3    .00000    .00000   -.07143    .07143   90.00000    .00000    .00100     2    3    4      0
  55.      4    .00000    .00000    .00000    .07143   90.00000    .00000    .00100     3    4    5      0
  56.      5    .00000    .00000    .07143    .07143   90.00000    .00000    .00100     4    5    6      0
  57.      6    .00000    .00000    .14286    .07143   90.00000    .00000    .00100     5    6    7      0
  58.      7    .00000    .00000    .21429    .07143   90.00000    .00000    .00100     6    7    0      0
  59.  
  60.  
  61.  
  62.  
  63.  
  64.  
  65.  ***** DATA CARD NO.  1   EX   0     0     4     0  1.00000E+00  0.00000E+00  0.00000E+00  0.00000E+00  0.00000E+00  0.00000E+00
  66.  ***** DATA CARD NO.  2   XQ   0     0     0     0  0.00000E+00  0.00000E+00  0.00000E+00  0.00000E+00  0.00000E+00  0.00000E+00
  67.  
  68.  
  69.  
  70.  
  71.                                  - - - - - - FREQUENCY - - - - - -
  72.  
  73.                                     FREQUENCY= 2.9980E+02 MHZ
  74.                                     WAVELENGTH= 1.0000E+00 METERS
  75.  
  76.  
  77.  
  78.  
  79.                     APPROXIMATE INTEGRATION EMPLOYED FOR SEGMENTS MORE THAN   1.000 WAVELENGTHS APART
  80.  
  81.  
  82.  
  83.                                - - - STRUCTURE IMPEDANCE LOADING - - -
  84.  
  85.                                    THIS STRUCTURE IS NOT LOADED
  86.  
  87.  
  88.  
  89.                                   - - - ANTENNA ENVIRONMENT - - -
  90.  
  91.                                             FREE SPACE
  92.  
  93.  
  94.  
  95.                                 - - - MATRIX TIMING - - -
  96.  
  97.                         FILL=     .050 SEC.,  FACTOR=     .000 SEC.
  98.  
  99.  
  100.  
  101.                                           - - - ANTENNA INPUT PARAMETERS - - -
  102.  
  103.    TAG   SEG.    VOLTAGE (VOLTS)         CURRENT (AMPS)         IMPEDANCE (OHMS)        ADMITTANCE (MHOS)      POWER
  104.    NO.   NO.    REAL        IMAG.       REAL        IMAG.       REAL        IMAG.       REAL        IMAG.     (WATTS)
  105.      0     4 1.00000E+00 0.00000E+00 9.20585E-03-5.15474E-03 8.26979E+01 4.63060E+01 9.20585E-03-5.15474E-03 4.60292E-03
  106.  
  107.  
  108.  
  109.                              - - - CURRENTS AND LOCATION - - -
  110.  
  111.                                  DISTANCES IN WAVELENGTHS
  112.  
  113.  
  114.   SEG.  TAG    COORD. OF SEG. CENTER     SEG.            - - - CURRENT (AMPS) - - -
  115.   NO.   NO.     X        Y        Z      LENGTH     REAL        IMAG.       MAG.        PHASE
  116.      1    0    .0000    .0000   -.2143   .07143   2.3592E-03 -1.6881E-03  2.9010E-03  -35.584
  117.      2    0    .0000    .0000   -.1429   .07143   5.9998E-03 -4.0463E-03  7.2367E-03  -33.996
  118.      3    0    .0000    .0000   -.0714   .07143   8.3711E-03 -5.1857E-03  9.8472E-03  -31.777
  119.      4    0    .0000    .0000    .0000   .07143   9.2058E-03 -5.1547E-03  1.0551E-02  -29.246
  120.      5    0    .0000    .0000    .0714   .07143   8.3711E-03 -5.1857E-03  9.8472E-03  -31.777
  121.      6    0    .0000    .0000    .1429   .07143   5.9998E-03 -4.0463E-03  7.2367E-03  -33.996
  122.      7    0    .0000    .0000    .2143   .07143   2.3592E-03 -1.6881E-03  2.9010E-03  -35.584
  123.  
  124.  
  125.  
  126.                                         - - - POWER BUDGET - - -
  127.  
  128.                                            INPUT POWER   = 4.6029E-03 WATTS
  129.                                            RADIATED POWER= 4.6029E-03 WATTS
  130.                                            STRUCTURE LOSS= 0.0000E+00 WATTS
  131.                                            NETWORK LOSS  = 0.0000E+00 WATTS
  132.                                            EFFICIENCY    = 100.00 PERCENT
  133.  
  134.  
  135.  
  136.  
  137.  
  138.  
  139.  ***** DATA CARD NO.  3   LD   0     0     4     4  1.00000E+01  3.00000E-09  5.30000E-11  0.00000E+00  0.00000E+00  0.00000E+00
  140.  ***** DATA CARD NO.  4   PQ   0     0     0     0  0.00000E+00  0.00000E+00  0.00000E+00  0.00000E+00  0.00000E+00  0.00000E+00
  141.  ***** DATA CARD NO.  5   NE   0     1     1    15  1.00000E-03  0.00000E+00  0.00000E+00  0.00000E+00  0.00000E+00  1.78600E-02
  142.  
  143.  
  144.  
  145.                                - - - STRUCTURE IMPEDANCE LOADING - - -
  146.  
  147.  
  148.        LOCATION          RESISTANCE   INDUCTANCE  CAPACITANCE       IMPEDANCE (OHMS)     CONDUCTIVITY    TYPE
  149.     ITAG FROM THRU          OHMS        HENRYS       FARADS        REAL      IMAGINARY    MHOS/METER
  150.  
  151.             4    4       .1000E+02    .3000E-08    .5300E-10                                           SERIES 
  152.  
  153.  
  154.  
  155.                                   - - - ANTENNA ENVIRONMENT - - -
  156.  
  157.                                             FREE SPACE
  158.  
  159.  
  160.  
  161.                                 - - - MATRIX TIMING - - -
  162.  
  163.                         FILL=     .050 SEC.,  FACTOR=     .000 SEC.
  164.  
  165.  
  166.  
  167.                                           - - - ANTENNA INPUT PARAMETERS - - -
  168.  
  169.    TAG   SEG.    VOLTAGE (VOLTS)         CURRENT (AMPS)         IMPEDANCE (OHMS)        ADMITTANCE (MHOS)      POWER
  170.    NO.   NO.    REAL        IMAG.       REAL        IMAG.       REAL        IMAG.       REAL        IMAG.     (WATTS)
  171.      0     4 1.00000E+00 0.00000E+00 8.95465E-03-4.05149E-03 9.26979E+01 4.19407E+01 8.95465E-03-4.05149E-03 4.47733E-03
  172.  
  173.  
  174.  
  175.                              - - - CURRENTS AND LOCATION - - -
  176.  
  177.                                  DISTANCES IN WAVELENGTHS
  178.  
  179.  
  180.   SEG.  TAG    COORD. OF SEG. CENTER     SEG.            - - - CURRENT (AMPS) - - -
  181.   NO.   NO.     X        Y        Z      LENGTH     REAL        IMAG.       MAG.        PHASE
  182.      1    0    .0000    .0000   -.2143   .07143   2.3241E-03 -1.3790E-03  2.7024E-03  -30.682
  183.      2    0    .0000    .0000   -.1429   .07143   5.8908E-03 -3.2779E-03  6.7413E-03  -29.093
  184.      3    0    .0000    .0000   -.0714   .07143   8.1824E-03 -4.1467E-03  9.1731E-03  -26.875
  185.      4    0    .0000    .0000    .0000   .07143   8.9547E-03 -4.0515E-03  9.8285E-03  -24.344
  186.      5    0    .0000    .0000    .0714   .07143   8.1824E-03 -4.1467E-03  9.1731E-03  -26.875
  187.      6    0    .0000    .0000    .1429   .07143   5.8908E-03 -3.2779E-03  6.7413E-03  -29.093
  188.      7    0    .0000    .0000    .2143   .07143   2.3241E-03 -1.3790E-03  2.7024E-03  -30.682
  189.  
  190.  
  191.  
  192.                                   - - - CHARGE DENSITIES - - -
  193.  
  194.                                     DISTANCES IN WAVELENGTHS
  195.  
  196.  
  197.   SEG.  TAG    COORD. OF SEG. CENTER     SEG.          CHARGE DENSITY (COULOMBS/METER)
  198.   NO.   NO.     X        Y        Z      LENGTH     REAL        IMAG.       MAG.        PHASE
  199.      1    0    .0000    .0000   -.2143   .07143   1.8292E-11  3.1761E-11  3.6652E-11   60.061
  200.      2    0    .0000    .0000   -.1429   .07143   1.0429E-11  2.2040E-11  2.4383E-11   64.676
  201.      3    0    .0000    .0000   -.0714   .07143   2.1140E-12  1.1638E-11  1.1829E-11   79.705
  202.      4    0    .0000    .0000    .0000   .07143   5.1684E-19  2.3814E-19  5.6906E-19   24.738
  203.      5    0    .0000    .0000    .0714   .07143  -2.1140E-12 -1.1638E-11  1.1829E-11 -100.295
  204.      6    0    .0000    .0000    .1429   .07143  -1.0429E-11 -2.2040E-11  2.4383E-11 -115.324
  205.      7    0    .0000    .0000    .2143   .07143  -1.8292E-11 -3.1761E-11  3.6652E-11 -119.939
  206.  
  207.  
  208.  
  209.                                         - - - POWER BUDGET - - -
  210.  
  211.                                            INPUT POWER   = 4.4773E-03 WATTS
  212.                                            RADIATED POWER= 3.9943E-03 WATTS
  213.                                            STRUCTURE LOSS= 4.8300E-04 WATTS
  214.                                            NETWORK LOSS  = 0.0000E+00 WATTS
  215.                                            EFFICIENCY    =  89.21 PERCENT
  216.  
  217.  
  218.  
  219.                                    - - - NEAR ELECTRIC FIELDS - - -
  220.  
  221.             -  LOCATION  -                     -  EX  -               -  EY  -               -  EZ  -
  222.         X          Y          Z          MAGNITUDE   PHASE      MAGNITUDE   PHASE      MAGNITUDE   PHASE
  223.       METERS     METERS     METERS        VOLTS/M   DEGREES      VOLTS/M   DEGREES      VOLTS/M   DEGREES
  224.         .0010      .0000      .0000     1.0228E-05    24.74    0.0000E+00      .00    1.3042E+01  -175.10
  225.         .0010      .0000      .0179     5.5442E+01   -66.31    0.0000E+00      .00    1.2537E+01  -175.08
  226.         .0010      .0000      .0357     1.0968E+02   -67.15    0.0000E+00      .00    6.7271E+00  -175.46
  227.         .0010      .0000      .0536     1.5608E+02   -88.85    0.0000E+00      .00    8.4339E-01  -179.75
  228.         .0010      .0000      .0714     2.1267E+02  -100.30    0.0000E+00      .00    4.2135E-04    -6.13
  229.         .0010      .0000      .0893     2.7147E+02  -106.86    0.0000E+00      .00    3.4497E-01    -8.87
  230.         .0010      .0000      .1072     3.2920E+02  -111.08    0.0000E+00      .00    2.8000E-01    22.83
  231.         .0010      .0000      .1250     3.8592E+02  -113.51    0.0000E+00      .00    2.2076E-01    74.41
  232.         .0010      .0000      .1429     4.3835E+02  -115.33    0.0000E+00      .00    3.0905E-04   -94.14
  233.         .0010      .0000      .1607     4.8563E+02  -116.77    0.0000E+00      .00    2.1937E-01  -106.41
  234.         .0010      .0000      .1786     5.2800E+02  -117.97    0.0000E+00      .00    1.9750E+00    57.57
  235.         .0010      .0000      .1965     5.9664E+02  -119.06    0.0000E+00      .00    3.3113E+00    58.63
  236.         .0010      .0000      .2143     6.5880E+02  -119.94    0.0000E+00      .00    9.9556E-03  -121.24
  237.         .0010      .0000      .2322     7.1246E+02  -120.67    0.0000E+00      .00    1.0680E+01  -121.66
  238.         .0010      .0000      .2500     5.5195E+02  -121.29    0.0000E+00      .00    3.8032E+02  -121.43
  239.  
  240.  
  241.  
  242.  
  243.  
  244.  
  245.  ***** DATA CARD NO.  6   EN   0     0     0     0  0.00000E+00  0.00000E+00  0.00000E+00  0.00000E+00  0.00000E+00  0.00000E+00
  246.  
  247.  RUN TIME =      .450
  248.